Brand Name : CY-Group
Model Number : CYS-A(S)T-15/600
Certification : KEMA CE ISO SGS TUV UC3
Place of Origin : China
MOQ : 1pcs
Price : NEGOTIABLE
Payment Terms : L/C, TT,D/A,D/P
Supply Ability : 6000000pcs/year
Delivery Time : 3-8 days
Packaging Details : Plymood
Material : RUBBER
Voltage Class : 15 kV
Voltage Rating : 8.3/14.4 kV
Rated Current : 200 A
AC Withstand Voltage 5min : 39 kV
DC Withstand Voltage 15min : 35 kV
Partial Discharge : 15 kV, ≤10 pC
BIL : 95 kV
Thermal Current : 10 kA, 0.6 s
Dynamic Current : 20 kA, 10 ms
Cable Section : 35 to 120mm2
Medium Voltage Separable Connectors 200A 25 kV Class Loadbreak Elbow Connector Tee Type
Application
Chuangyin® Tee Connector is widely applicable for connecting a power cable to two in-line bushing interfaces. It designed to terminate underground cables to high-voltage apparatus such as transformers, switchgear, junction box. This allows the use of the fault indicators (energized indicator), and provides a hotstick operable.
Cable Section: 25 to 400 mm2
The interface complys with IEEE standard 386, 8.3/14.4 kV, 600 A deadbreak design.
Features
Made of high quality EPDM rubber
Connecting a power cable to two in-line bushing interfaces
Fully shielded, submersible connection for deadbreak system
With/Without test point
100% factory tested
In compliance with IEC standard 386
Construction
1. Bolt
2. Lug
3. Semi-conducting Shield
4. Insulating Layer
5. Adapter
6. Insulated Cap
7. Insulating Plug
8. Semi-conducting Insert
9. Test Point
10. Grounding Tab
Technical Data
Item | Parameters |
Voltage Class | 15 kV |
Voltage Rating | 8.3/14.4 kV |
AC Withstand Voltage 5min | 39 kV |
DC Withstand Voltage 15min | 35 kV |
Partial Discharge | 15 kV, ≤10 pC |
BIL | 95 kV |
Thermal Current | 23 kA, 2 s |
Dynamic Current | 84 kA, 10 ms |
Cable Section | 25 to 400 mm2 |
Kit Contents
T-Body Connector
Insulating Plug
Insulated Cap
Adapter
Lug
Bolt
Wipers
Silicone Grease
Installation Tools
Installation instruction
Certificate
Ordering Instructions
Part Number | Cable Section (mm²) | Diameter over Insulation (mm) | Code |
CYS-A(S)T-15/600-25 | 25 | 16 to 17.8 | A |
CYS-A(S)T-15/600-35 | 35 | 17 to 19 | B |
CYS-A(S)T-15/600-50 | 50 | 18 to 20 | B |
CYS-A(S)T-15/600-70 | 70 | 20 to 21.4 | C |
CYS-A(S)T-15/600-95 | 95 | 21.6 to 23.1 | C |
CYS-A(S)T-15/600-120 | 120 | 23 to 24.6 | D |
CYS-A(S)T-15/600-150 | 150 | 24.4 to 26.1 | D |
CYS-A(S)T-15/600-185 | 185 | 25.8 to 27.8 | E |
CYS-A(S)T-15/600-240 | 240 | 28 to 30 | E |
CYS-A(S)T-15/600-300 | 300 | 30.4 to 32.3 | F |
CYS-A(S)T-15/600-400 | 400 | 33 to 35.4 | G |
![]() |
Medium Voltage Separable Connectors 200 A 25 kV Class Loadbreak Elbow Connector T Type Images |